COOLANT DISTRIBUTION UNITS (CDUs)

CoolIT CHx™ 80: In-Rack CDU for HPC and Enterprise

The CHx™ 80 is a rack-based CDU, built for today’s HPC and enterprise server requirements. Capable of managing 80 kW of heat load in a remarkably small 4U of space, this system provides cooling for up to 100 servers.

COOLANT DISTRIBUTION UNITS (CDUs)

CoolIT CHx™ 80: In-Rack CDU for HPC and Enterprise

AHx180 liquid cooling module with front panel display and airflow grille.
A 3D product rendering of a grey rack-mounted server chassis with its top metal cover partially lifted, revealing the internal electronic circuit boards and cooling modules.
AHx180 liquid cooling module with front panel display and airflow grille.
A 3D product rendering of a grey rack-mounted server chassis with its top metal cover partially lifted, revealing the internal electronic circuit boards and cooling modules.
Benefits
  • Manage up to 100 servers per rack
  • Warm water cooling reduces the need for chillers
  • Quick and easy installation and service
  • Install at the bottom or top of server rack
  • Servers remain hot-swappable for service
  • Supports ASHRAE W+ warm water cooling & lower temperature ranges, enabling free cooling & heat reuse.
Features
CHx80 coolant distribution unit for scalable direct-to-chip cooling infrastructure.

The CHx80 CDU for In-Rack HPC and Enterprise Deployments

The CHx80 is built for HPC and enterprise deployments that need direct liquid cooling at entry rack capacity. It sits inside a standard 4U rack slot and cools up to 100 high-TDP servers in the same rack, without adding row-based infrastructure.

Standard HPC Server Racks

Up to 100 high-TDP HPC servers cooled from within the rack, at 80 kW of total cooling capacity per CHx80 unit.

Enterprise Data Center Retrofits

Install the CHx80 in the top or bottom of an existing 19-inch server rack. No row-based CDU footprint, no dedicated cooling aisle, no floor plan redesign.

Warm-Water and Free-Cooling Sites

ASHRAE W17 to W+ compatibility enables chiller-free operation in most climates and heat-reuse strategies where facility infrastructure supports it.

CoolIT CHx80 in-rack coolant distribution unit with the top panel removed to show internal components.
Density By Design

80 kW of Direct Liquid Cooling in a 4U Rack Slot

The CHx80 delivers 80 kW of direct liquid cooling in just 4U of rack space, with warm-water compatibility and N+1 redundancy.

Rack-Integrated Cooling with No Row-Based Footprint

The CHx80 installs inside the server rack, enabling rack-by-rack liquid cooling without dedicated row-based CDU infrastructure.

 Up to 100 Servers per Rack

One CHx80 can cool up to 100 servers and mount at the top or bottom of the rack, while servers remain hot-swappable for service.

Warm-Water Compatible Across the ASHRAE Range (W17 to W+)

ASHRAE W17 to W+ compatibility supports chilled or warm-water operation, enabling free cooling and heat reuse where infrastructure allows.

N+1 Redundant Pumps and Power

N+1 pumps and power supplies help maintain cooling through a single component failure, with intelligent controls and integrated leak detection.

Frequently Asked Questions

Does the CHx80 need facility water?

What ASHRAE water classes does the CHx80 support?

How many servers can one CHx80 cool?

Where does the CHx80 mount inside the rack?

How is redundancy handled in the CHx80?

Can the CHx80 support chiller-free deployments?

Related Blog Articles

News

Air Cooling vs Liquid Cooling for AI and HPC: Which Is the Better Fit?

JANUARY 3, 2024

Blog Posts

Direct-to-Chip Liquid Cooling: Boosting AI Data Center Performance

JULY 24, 2025

News

Data Center Cooling Systems: A Beginner’s Technical Guide

DECEMBER 3, 2025

A perspective view of four tall, black industrial cooling cabinets lined up on a grey concrete floor in a large, brightly lit warehouse.