COOLANT DISTRIBUTION UNITS (CDUs)

CoolIT CHx™200: In-Rack CDU for HPC and Enterprise

CoolIT CHx™200 is a rack-based CDU, built for the needs of today’s most demanding HPC and enterprise server requirements. Capable of managing 200 kW of heat load in a remarkably small 4U of space, this system provides cooling for up to 200 servers.

COOLANT DISTRIBUTION UNITS (CDUs)

CoolIT CHx™200: In-Rack CDU for HPC and Enterprise

CoolIT Rack DCLC CHx200 rear view with liquid connections, power inputs, and high-capacity cooling loop interface.
CoolIT CHx200 coolant distribution unit with exposed internal components, pumps, and multiple quick-connect ports for direct liquid cooling systems.
A studio shot showing the rear panel of a silver metal server unit, featuring large circular fluid ports, electrical sockets, and various green and black connection ports.
CoolIT Rack DCLC CHx200 rear view with liquid connections, power inputs, and high-capacity cooling loop interface.
CoolIT CHx200 coolant distribution unit with exposed internal components, pumps, and multiple quick-connect ports for direct liquid cooling systems.
A studio shot showing the rear panel of a silver metal server unit, featuring large circular fluid ports, electrical sockets, and various green and black connection ports.
Benefits
  • Manage up to 200 servers per rack
  • Warm water cooling reduces the need for chillers
  • Quick and easy installation and service
  • Install at the bottom or top of server rack
  • Servers remain hot-swappable for service
  • Supports ASHRAE W+ warm water cooling & lower temperature ranges, enabling free cooling & heat reuse.
Features
CoolIT CHx200 coolant distribution unit with exposed internal components, pumps, and multiple quick-connect ports for direct liquid cooling systems.

The CHx200 CDU for In-Rack Direct Liquid Cooling

The CHx200 is built for HPC and enterprise deployments that need direct liquid cooling without adding row-based infrastructure. It sits inside a standard 4U rack slot and cools up to 200 high-TDP servers in the same rack.

HPC Server Racks

Up to 200 high-TDP HPC servers cooled from within the rack, at 200 kW of total cooling capacity per CHx200 unit.

Enterprise Data Centers Without Row-Based Rebuilds

Install the CHx200 in the top or bottom of an existing 19-inch server rack. No row-based CDU footprint, no dedicated cooling aisle, no floor plan redesign.

Warm-Water and Free-Cooling Deployments

ASHRAE W17 to W+ compatibility enables chiller-free operation in most climates and heat-reuse strategies where facility infrastructure supports it.

CoolIT CHx200 in-rack coolant distribution unit in a 4U rack-mount chassis for HPC and enterprise cooling.
Density By Design

200 kW of Direct Liquid Cooling Inside the Rack

The CHx200 delivers 200 kW of direct liquid cooling in just 4U of rack space, with warm-water compatibility and N+1 redundancy for continuous operation.

200 kW in a 4U Slot

The CHx200 delivers 200 kW of cooling from a 4U rack-mount chassis, eliminating the need for a separate row-based CDU footprint.

 Up to 200 Servers per Rack

One CHx200 can cool up to 200 servers and mount at the top or bottom of the rack. Servers remain hot-swappable for easier service.

Warm-Water Compatible Across the ASHRAE Range (W17 to W+)

ASHRAE W17 to W+ compatibility supports chilled or warm-water operation, enabling free cooling and heat reuse where facility conditions allow.

N+1 Redundant Pumps and Power

N+1 pumps and power supplies help keep cooling online through a single component failure, while intelligent controls provide continuous leak monitoring.

Frequently Asked Questions

Does the CHx200 need facility water?

How many servers can one CHx200 cool?

What ASHRAE water classes does the CHx200 support?

Where does the CHx200 mount inside the rack?

How is redundancy handled in the CHx200?

Can the CHx200 support chiller-free deployments?

Related Blog Articles

Blog Posts

In-Rack Cooling vs In-Row Cooling: Improving Data Center Efficiency

JULY 24, 2025

In-row cooling unit positioned beside server racks with overhead coolant distribution piping.